Przeglądanie stron 12
13
Wiring Quick Reference Guide
LED
Valet
Switch
GREEN/BLACK Lock #30 Common Output
WHITE/BLUE (-) 200 mA Channel 3 Valididty Output
BLACK/WHITE Output of Domelight Supervision Relay #87
LT. GREEN/BLACK Factory Alarm Disarm
BLACK/WHITE-1 Input of Domelight Supervision Relay #87
BROWN (-) Horn Honk Output
BLUE (-) 200mA 2nd Unlock Output
BLACK (-) Chassis Ground Input
RED (+) 12V Constant Power Input
WHITE (+/-) Light Flash Output
YELLOW (+) Switched Ignition Input (Accessory)
WHITE/BLACK Lock #87 Normally Closed
ORANGE (-) 500 mA Ground-When-Armed Output
VIOLET/BLACK Lock #87 Normally Open (Input)
BROWN/BLACK Unlock #87A Normally Closed
BLUE/BLACK Unlock #30 Common Output
RED/WHITE (-) Output of Channel 2
VIOLET Unlock #87 Normally Open (Input)
LIGHT FLASH JUMPER